Your fire safety responsibilities, in plain English

If you own, manage or control a non-domestic building, the law makes you the “responsible person” for fire safety. Here is what that means, and how often your fire safety equipment needs testing.

Who is the responsible person?

Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person is usually the employer, the owner, or whoever has control of the premises, such as a landlord, managing agent or facilities manager. In a shared building there may be more than one, and you must work together.

What the law asks you to do

  • Have a suitable and sufficient fire risk assessment, and keep it up to date.
  • Since October 2023, record the whole fire risk assessment and your fire safety arrangements in writing, whatever the size of your business, including the name of the person who carried it out.
  • Use a competent person for your fire risk assessment if you do not have the knowledge in-house.
  • Put the right fire safety measures in place: detection and alarms, emergency lighting, firefighting equipment, fire doors and clear escape routes.
  • Keep those measures maintained in good working order, and keep records of testing and servicing.
  • Give staff the information and training they need, and plan for emergencies, including fire drills.

How often should things be tested?

These are the usual intervals from the relevant British Standards. Your fire risk assessment may ask for something different, and that takes priority.

EquipmentYou (in-house)A competent engineer
Fire alarm
BS 5839-1
Test a different call point every week and record itInspect and service at least every six months
Emergency lighting
BS 5266-1
Short functional test every monthFull-duration test every year
Fire extinguishers
BS 5306-3
Visual check every monthService every year; extended service every 5 years (water, foam, powder) and every 10 years (CO2)
Fire doorsRegular checks that doors close fully and are not wedged openInspection by a competent person, typically every six months
Dry risers
BS 9990
Keep inlets and outlets clear and secureVisual inspection every six months; pressure test every year
Fire dampers–Test at least every year
Smoke ventsRegular operational checksService at least every year
Fire drills and trainingFire drill at least once a year; training for new startersFire marshal and warden training

Keep the evidence

If the fire service inspects, or something goes wrong, you will need to show that testing has been done. All of our maintenance customers get their certificates, service reports and defects online in the A&E Customer Portal, ready whenever you are asked.

Not sure where you stand?

We can review your building, tell you what is missing and put a single maintenance programme in place for everything on this page.

Book a free Fire & Security Health CheckFire risk assessments

This page is general guidance for premises in England and Wales, not legal advice.